ELECTRICAL
| PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
|---|---|---|---|
| Hot-Wire Ignition (HWI), PLC 1 | ≥0.8 | mm | UL 746A |
| Hot-Wire Ignition (HWI), PLC 0 | ≥3 | mm | UL 746A |
| High Amp Arc Ignition (HAI), PLC 0 | ≥0.8 | mm | UL 746A |
| Comparative Tracking Index | 600 | V | IEC 60112 |
LNP ELCRIN WF0061BiQ is a 30% glass fiber reinforced, non-brominated, non-chlorinated flame-retardant Polybutylene Terephthalate (PBT) compound, utilizing iQ PBT chemical recycling process of Ocean Bound PET water bottles with minimum 26% ocean bound (OB) recycled content certified by UL 2809. Added features of this material include: good flow and UL V-0 rating at 0.8 mm thickness.
All colors are customizable. Refer our ColorXpress tool to check color availability
| PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
|---|---|---|---|
| Hot-Wire Ignition (HWI), PLC 1 | ≥0.8 | mm | UL 746A |
| Hot-Wire Ignition (HWI), PLC 0 | ≥3 | mm | UL 746A |
| High Amp Arc Ignition (HAI), PLC 0 | ≥0.8 | mm | UL 746A |
| Comparative Tracking Index | 600 | V | IEC 60112 |
| PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
|---|---|---|---|
| UL Yellow Card Link | View | - | - |
| UL Recognized, 94V-0 Flame Class Rating | ≥0.8 | mm | UL 94 |
| UL Recognized, 94-5VB Flame Class Rating | ≥3.0 | mm | UL 94 |
| Glow Wire Ignitability Temperature, 3.0 mm | 800 | °C | IEC 60695-2-13 |
| Glow Wire Ignitability Temperature, 1.5 mm | 775 | °C | IEC 60695-2-13 |
| Glow Wire Ignitability Temperature, 0.8 mm | 750 | °C | IEC 60695-2-13 |
| Glow Wire Flammability Index, 3.0 mm | 960 | °C | IEC 60695-2-12 |
| Glow Wire Flammability Index, 1.5 mm | 960 | °C | IEC 60695-2-12 |
| Glow Wire Flammability Index, 0.8 mm | 960 | °C | IEC 60695-2-12 |
| PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
|---|---|---|---|
| Izod Impact, unnotched, 23°C | 540 | J/m | ASTM D4812 |
| Izod Impact, notched, 23°C | 64 | J/m | ASTM D256 |
| Izod Impact, notched, -30°C | 59 | J/m | ASTM D256 |
| Instrumented Dart Impact Total Energy, 23°C | 6 | J | ASTM D3763 |
| Instrumented Dart Impact Energy @ peak, 23°C | 5 | J | ASTM D3763 |
| Instrumented Dart Impact Peak Force, 23°C | 1200 | N | ASTM D3763 |
| Izod Impact, unnotched 80*10*4 +23°C | 39 | kJ/m² | ISO 180/1U |
| Izod Impact, notched 80*10*4 +23°C | 8.5 | kJ/m² | ISO 180/1A |
| Izod Impact, notched 80*10*4 -30°C | 8 | kJ/m² | ISO 180/1A |
| PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
|---|---|---|---|
| Drying Temperature | 110 - 120 | °C | |
| Drying Time | 2 - 4 | Hrs | |
| Maximum Moisture Content | 0.02 | % | |
| Melt Temperature | 245 - 260 | °C | |
| Nozzle Temperature | 230 - 255 | °C | |
| Front - Zone 3 Temperature | 240 - 260 | °C | |
| Middle - Zone 2 Temperature | 235 - 250 | °C | |
| Rear - Zone 1 Temperature | 230 - 240 | °C | |
| Hopper Temperature | 40 - 60 | °C | |
| Mold Temperature | 40 - 100 | °C |
| PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
|---|---|---|---|
| Tensile Stress, brk, Type I, 5 mm/min | 104 | MPa | ASTM D638 |
| Tensile Strain, brk, Type I, 5 mm/min | 2 | % | ASTM D638 |
| Tensile Modulus, 5 mm/min | 10800 | MPa | ASTM D638 |
| Flexural Stress, brk, 1.3 mm/min, 50 mm span | 165 | MPa | ASTM D790 |
| Flexural Modulus, 1.3 mm/min, 50 mm span | 10300 | MPa | ASTM D790 |
| Tensile Stress, break, 5 mm/min | 102 | MPa | ISO 527 |
| Tensile Strain, break, 5 mm/min | 2 | % | ISO 527 |
| Tensile Modulus, 1 mm/min | 10720 | MPa | ISO 527 |
| Flexural Stress, break, 2 mm/min | 162 | MPa | ISO 178 |
| Flexural Modulus, 2 mm/min | 10570 | MPa | ISO 178 |
| PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
|---|---|---|---|
| Specific Gravity | 1.57 | - | ASTM D792 |
| Melt Flow Rate, 250°C/5.0 kgf | 24 | g/10 min | ASTM D1238 |
| Density | 1.54 | g/cm³ | ISO 1183 |
| Water Absorption, (23°C/24hrs) | 0.08 | % | ISO 62-1 |
| Moisture Absorption, (23°C/50% RH/24hrs) | 0.03 | % | ISO 62-4 |
| Melt Volume Rate, MVR at 250°C/5.0 kg | 17 | cm³/10 min | ISO 1133 |
| Mold Shrinkage, flow | 0.4 | % | SABIC method |
| Mold Shrinkage, xflow | 0.8 | % | SABIC method |
| PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
|---|---|---|---|
| HDT, 1.82 MPa, 3.2mm, unannealed | 204 | °C | ASTM D648 |
| HDT, 0.45 MPa, 3.2 mm, unannealed | 217 | °C | ASTM D648 |
| Vicat Softening Temp, Rate B/50 | 200 | °C | ASTM D1525 |
| Vicat Softening Temp, Rate B/120 | 201 | °C | ASTM D1525 |
| CTE, -40°C to 40°C, flow | 2.2E-05 | 1/°C | ASTM E831 |
| CTE, -40°C to 40°C, xflow | 8.5E-05 | 1/°C | ASTM E831 |
| HDT/Af, 1.8 MPa Flatw 80*10*4 sp=64mm | 202 | °C | ISO 75/Af |
| HDT/Bf, 0.45 MPa Flatw 80*10*4 sp=64mm | 217 | °C | ISO 75/Bf |
| Ball Pressure Test, approximate maximum | 175 | °C | IEC 60695-10-2 |
| Relative Temp Index, Elec | 75 | °C | UL 746B |
| Relative Temp Index, Mech w/impact | 75 | °C | UL 746B |
| Relative Temp Index, Mech w/o impact | 75 | °C | UL 746B |