ELECTRICAL
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Hot-Wire Ignition (HWI), PLC 0 | ≥3 | mm | UL 746A |
Hot-Wire Ignition (HWI), PLC 1 | ≥1.5 | mm | UL 746A |
High Amp Arc Ignition (HAI), PLC 0 | ≥1.5 | mm | UL 746A |
LNP LUBRICOMP WFL36E compound is based on Polybutylene Terephthalate (PBT) resin containing 30% glass fiber and 15% PTFE. Added features of this grade include: Easy Molding and Wear Resistant.
All colors are customizable. Refer our ColorXpress tool to check color availability
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Hot-Wire Ignition (HWI), PLC 0 | ≥3 | mm | UL 746A |
Hot-Wire Ignition (HWI), PLC 1 | ≥1.5 | mm | UL 746A |
High Amp Arc Ignition (HAI), PLC 0 | ≥1.5 | mm | UL 746A |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
UL Yellow Card Link | View | - | - |
UL Recognized, 94HB Flame Class Rating | ≥1.5 | mm | UL 94 |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Izod Impact, unnotched 80*10*4 +23°C | 45 | kJ/m² | ISO 180/1U |
Izod Impact, notched 80*10*4 +23°C | 10 | kJ/m² | ISO 180/1A |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Drying Temperature | 120 | °C | |
Drying Time | 4 | Hrs | |
Maximum Moisture Content | 0.05 | % | |
Melt Temperature | 240 - 265 | °C | |
Front - Zone 3 Temperature | 260 - 270 | °C | |
Middle - Zone 2 Temperature | 245 - 255 | °C | |
Rear - Zone 1 Temperature | 220 - 230 | °C | |
Mold Temperature | 80 - 100 | °C | |
Back Pressure | 0.2 - 0.3 | MPa | |
Screw Speed | 30 - 60 | rpm |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Tensile Stress, break, 5 mm/min | 114 | MPa | ISO 527 |
Tensile Strain, break, 5 mm/min | 2.5 | % | ISO 527 |
Tensile Modulus, 1 mm/min | 10100 | MPa | ISO 527 |
Flexural Stress, yield, 2 mm/min | 175 | MPa | ISO 178 |
Flexural Stress, break, 2 mm/min | 172 | MPa | ISO 178 |
Flexural Strain, break, 2 mm/min | 2.7 | % | ISO 178 |
Flexural Modulus, 2 mm/min | 9500 | MPa | ISO 178 |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Mold Shrinkage, flow | 0.1 - 0.3 | % | SABIC method |
Wear Factor Washer | 24 | 10^-10 in^5-min/ft-lb-hr | ASTM D3702 Modified: Instr. |
Dynamic COF | 0.54 | - | ASTM D3702 Modified: Instr. |
Static COF | 0.58 | - | ASTM D3702 Modified: Instr. |
Density | 1.7 | g/cm³ | ISO 1183 |
Water Absorption, (23°C/24hrs) | 0.04 | % | ISO 62-1 |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
CTE, 23°C to 60°C, flow | 2.E-05 | 1/°C | ISO 11359-2 |
CTE, 23°C to 60°C, xflow | 1.2E-04 | 1/°C | ISO 11359-2 |
HDT/Bf, 0.45 MPa Flatw 80*10*4 sp=64mm | 220 | °C | ISO 75/Bf |
HDT/Af, 1.8 MPa Flatw 80*10*4 sp=64mm | 207 | °C | ISO 75/Af |
Relative Temp Index, Elec | 75 | °C | UL 746B |
Relative Temp Index, Mech w/impact | 75 | °C | UL 746B |
Relative Temp Index, Mech w/o impact | 75 | °C | UL 746B |