ELECTRICAL
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Volume Resistivity | 1.E+03 | Ω.cm | ASTM D257 |
Surface Resistivity | 1.E+06 | Ω | ASTM D257 |
Static Decay, 5000V to <50V | <0.01 | Seconds | FTMS101B |
Hot-Wire Ignition (HWI), PLC 0 | ≥1 | mm | UL 746A |
High Amp Arc Ignition (HAI), PLC 0 | ≥1 | mm | UL 746A |