ELECTRICAL
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Hot-Wire Ignition (HWI), PLC 0 | ≥0.6 | mm | UL 746A |
High Amp Arc Ignition (HAI), PLC 0 | ≥0.6 | mm | UL 746A |
High Voltage Arc Track Rate {PLC} | 2 | PLC Code | UL 746A |
Comparative Tracking Index (UL) {PLC} | 3 | PLC Code | UL 746A |
Arc Resistance, Tungsten {PLC} | 7 | PLC Code | ASTM D495 |
Comparative Tracking Index | 200 | V | IEC 60112 |
Volume Resistivity | 1.E16 - 1.E17 | Ω.cm | IEC 62631-3-1 |
Dielectric Strength, in oil, 1.0 mm | 37 | kV/mm | IEC 60243-1 |
Dielectric Constant, 1.1 GHz | 3.07 | - | SABIC method |
Dielectric Constant, 1.9 GHz | 3.06 | - | SABIC method |
Dielectric Constant, 5 GHz | 3.06 | - | SABIC method |
Dielectric Constant, 10 GHz | 3.05 | - | SABIC method |
Dissipation Factor, 1.1 GHz | 0.0067 | - | SABIC method |
Dissipation Factor, 1.9 GHz | 0.0065 | - | SABIC method |
Dissipation Factor, 5 GHz | 0.0069 | - | SABIC method |
Dissipation Factor, 10 GHz | 0.0069 | - | SABIC method |