FLAME CHARACTERISTICS
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
UL Yellow Card Link | View | - | - |
UL Recognized, 94V-1 Flame Class Rating | ≥3 | mm | UL 94 |
UL Recognized, 94V-2 Flame Class Rating | ≥1.5 | mm | UL 94 |
LNP THERMOCOMP DF008ER compound is based on Polycarbonate (PC) resin containing 40% glass fiber. Added features of this grade include: Easy Molding, Mold Release.
All colors are customizable. Refer our ColorXpress tool to check color availability
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
UL Yellow Card Link | View | - | - |
UL Recognized, 94V-1 Flame Class Rating | ≥3 | mm | UL 94 |
UL Recognized, 94V-2 Flame Class Rating | ≥1.5 | mm | UL 94 |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Izod Impact, unnotched, 23°C | 450 | J/m | ASTM D4812 |
Izod Impact, notched, 23°C | 80 | J/m | ASTM D256 |
Instrumented Dart Impact Energy @ peak, 23°C | 13 | J | ASTM D3763 |
Multiaxial Impact | 2 | J | ISO 6603 |
Izod Impact, unnotched 80*10*4 +23°C | 60 | kJ/m² | ISO 180/1U |
Izod Impact, notched 80*10*4 +23°C | 14 | kJ/m² | ISO 180/1A |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Drying Temperature | 120 | °C | |
Drying Time | 4 | Hrs | |
Maximum Moisture Content | 0.02 | % | |
Melt Temperature | 305 - 325 | °C | |
Front - Zone 3 Temperature | 320 - 330 | °C | |
Middle - Zone 2 Temperature | 310 - 320 | °C | |
Rear - Zone 1 Temperature | 295 - 305 | °C | |
Mold Temperature | 80 - 110 | °C | |
Back Pressure | 0.2 - 0.3 | MPa | |
Screw Speed | 30 - 60 | rpm |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Tensile Stress, break | 136 | MPa | ASTM D638 |
Tensile Strain, break | 2.3 | % | ASTM D638 |
Tensile Modulus, 50 mm/min | 11810 | MPa | ASTM D638 |
Flexural Stress | 204 | MPa | ASTM D790 |
Flexural modulus | 11260 | MPa | ASTM D790 |
Tensile Stress, break | 136 | MPa | ISO 527 |
Tensile Strain, break | 2.2 | % | ISO 527 |
Tensile Modulus, 1 mm/min | 10800 | MPa | ISO 527 |
Flexural Stress | 203 | MPa | ISO 178 |
Flexural Modulus | 10970 | MPa | ISO 178 |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Moisture Absorption, (23°C/50% RH/24 hrs) | 0.93 | % | ASTM D570 |
Mold Shrinkage, flow, 24 hrs | 0.2 | % | ASTM D955 |
Mold Shrinkage, xflow, 24 hrs | 0.4 | % | ASTM D955 |
Mold Shrinkage, flow, 24 hrs | 0.16 | % | ISO 294 |
Mold Shrinkage, xflow, 24 hrs | 0.35 | % | ISO 294 |
Moisture Absorption (23°C / 50% RH) | 0.12 | % | ISO 62 |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
HDT, 1.82 MPa, 3.2mm, unannealed | 136 | °C | ASTM D648 |
CTE, -40°C to 40°C, flow | 3.25E-05 | 1/°C | ASTM E831 |
CTE, -40°C to 40°C, xflow | 3.5E-05 | 1/°C | ASTM E831 |
CTE, -40°C to 40°C, flow | 3.26E-05 | 1/°C | ISO 11359-2 |
CTE, -40°C to 40°C, xflow | 3.51E-05 | 1/°C | ISO 11359-2 |
HDT/Af, 1.8 MPa Flatw 80*10*4 sp=64mm | 139 | °C | ISO 75/Af |
Relative Temp Index, Elec | 80 | °C | UL 746B |
Relative Temp Index, Mech w/impact | 80 | °C | UL 746B |
Relative Temp Index, Mech w/o impact | 80 | °C | UL 746B |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
UL Yellow Card Link | View | - | - |
UL Recognized, 94V-1 Flame Class Rating | ≥3 | mm | UL 94 |
UL Recognized, 94V-2 Flame Class Rating | ≥1.5 | mm | UL 94 |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Izod Impact, unnotched 80*10*4 +23°C | 60 | kJ/m² | ISO 180/1U |
Izod Impact, notched 80*10*4 +23°C | 14 | kJ/m² | ISO 180/1A |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Tensile Stress, break, 5 mm/min | 158 | MPa | ISO 527 |
Tensile Strain, break, 5 mm/min | 2.3 | % | ISO 527 |
Tensile Modulus, 1 mm/min | 10800 | MPa | ISO 527 |
Flexural Stress, yield, 2 mm/min | 222 | MPa | ISO 178 |
Flexural Modulus, 2 mm/min | 9500 | MPa | ISO 178 |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Mold Shrinkage on Tensile Bar, flow | 0.1 - 0.3 | % | SABIC method |
Density | 1.51 | g/cm³ | ISO 1183 |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
CTE, 23°C to 60°C, flow | 1.6E-05 | 1/°C | ISO 11359-2 |
CTE, 23°C to 60°C, xflow | 6.E-05 | 1/°C | ISO 11359-2 |
HDT/Bf, 0.45 MPa Flatw 80*10*4 sp=64mm | 145 | °C | ISO 75/Bf |
HDT/Af, 1.8 MPa Flatw 80*10*4 sp=64mm | 139 | °C | ISO 75/Af |
Relative Temp Index, Elec | 80 | °C | UL 746B |
Relative Temp Index, Mech w/impact | 80 | °C | UL 746B |
Relative Temp Index, Mech w/o impact | 80 | °C | UL 746B |