ELECTRICAL
| PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
|---|---|---|---|
| Surface Resistivity, ROA | >1.E+16 | Ω | IEC 60093 |
| Volume Resistivity | >1.E+16 | Ω.cm | IEC 60093 |
| Comparative Tracking Index | 500 | V | IEC 60112 |
| Comparative Tracking Index, M | 375 | V | IEC 60112 |
| Dielectric Strength, in oil, 3.2 mm | 20 | kV/mm | IEC 60243-1 |
| Relative Permittivity, 1 MHz | 3.4 | - | IEC 60250 |
| Dissipation Factor, 1 MHz | 0.016 | - | IEC 60250 |
| Relative Permittivity, 50/60 Hz | 3.6 | - | IEC 60250 |
| Dissipation Factor, 50/60 Hz | 0.0061 | - | IEC 60250 |