ELECTRICAL
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Dielectric Strength, in oil, 3.2 mm | 19.7 | kV/mm | ASTM D149 |
Relative Permittivity, 50/60 Hz | 2.65 | - | ASTM D150 |
Dissipation Factor, 50/60 Hz | 0.0004 | - | ASTM D150 |
High Voltage Arc Track Rate {PLC} | 4 | PLC Code | UL 746A |
Comparative Tracking Index (UL) {PLC} | 3 | PLC Code | UL 746A |
High Amp Arc Ignition (HAI), PLC 0 | ≥1.5 | mm | UL 746A |
High Amp Arc Ignition (HAI), PLC 4 | ≥6 | mm | UL 746A |
Hot-Wire Ignition (HWI), PLC 2 | ≥1.5 | mm | UL 746A |
Hot-Wire Ignition (HWI), PLC 4 | ≥6 | mm | UL 746A |
Arc Resistance, Tungsten {PLC} | 7 | PLC Code | ASTM D495 |