ELECTRICAL
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Comparative Tracking Index (UL) {PLC} | 1 | PLC Code | UL 746A |
Hot-Wire Ignition (HWI), PLC 0 | ≥0.4 | mm | UL 746A |
High Amp Arc Ignition (HAI), PLC 0 | ≥0.8 | mm | UL 746A |
LNP LUBRICOMP UX05051 compound is based on Polyphthalamide (PPA) resin containing glass fiber and PTFE. Added features of this grade include: Heat Stabilized, Flame Retardant, Hot Water Moldable, Wear Resistant.
All colors are customizable. Refer our ColorXpress tool to check color availability
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Comparative Tracking Index (UL) {PLC} | 1 | PLC Code | UL 746A |
Hot-Wire Ignition (HWI), PLC 0 | ≥0.4 | mm | UL 746A |
High Amp Arc Ignition (HAI), PLC 0 | ≥0.8 | mm | UL 746A |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
UL Yellow Card Link | View | - | - |
UL Recognized, 94V-0 Flame Class Rating | 0.4 | mm | UL 94 |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Izod Impact, unnotched 80*10*4 +23°C | 25 | kJ/m² | ISO 180/1U |
Izod Impact, notched 80*10*4 +23°C | 8 | kJ/m² | ISO 180/1A |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Drying Temperature | 80 | °C | |
Drying Time | 4 | Hrs | |
Melt Temperature | 305 - 315 | °C | |
Front - Zone 3 Temperature | 305 - 320 | °C | |
Middle - Zone 2 Temperature | 305 - 320 | °C | |
Rear - Zone 1 Temperature | 305 - 320 | °C | |
Mold Temperature | 95 - 120 | °C | |
Back Pressure | 0.3 - 0.7 | MPa | |
Screw Speed | 30 - 60 | rpm |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Tensile Stress, break, 5 mm/min | 138 | MPa | ISO 527 |
Tensile Strain, break, 5 mm/min | 1 | % | ISO 527 |
Tensile Modulus, 1 mm/min | 12100 | MPa | ISO 527 |
Flexural Stress, yield, 2 mm/min | 188 | MPa | ISO 178 |
Flexural Modulus, 2 mm/min | 10700 | MPa | ISO 178 |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
Density | 1.76 | g/cm³ | ISO 1183 |
PROPERTIES | TYPICAL VALUES | UNITS | TEST METHODS |
---|---|---|---|
CTE, 23°C to 60°C, flow | 2.E-05 | 1/°C | ISO 11359-2 |
CTE, 23°C to 60°C, xflow | 5.2E-05 | 1/°C | ISO 11359-2 |
HDT/Af, 1.8 MPa Flatw 80*10*4 sp=64mm | 273 | °C | ISO 75/Af |
Relative Temp Index, Elec | 140 | °C | UL 746B |
Relative Temp Index, Mech w/impact | 65 | °C | UL 746B |
Relative Temp Index, Mech w/o impact | 140 | °C | UL 746B |
Your PDF is downloading. Please wait.